R&L Electronics
Text Questions to
513-868-6399
800-221-7735

   Catalog » WATTMETERS » WATTMETERPP My Account | Cart Contents | Checkout   


Search
 
Use keywords to find the product you are looking for.
Advanced Search
Icom
Jetstream
Kenwood
MFJ
Yaesu

Used Equipment

Links

Screen Savers
Brand
Email
Email
Subscribe to our email list
Unsubscribe to our email list
Catalog
Request Catalog
Download eCatalog
Store Info
FAQ
Map to Store
Special Events
Store Hours

POWERWERX WATTMETERPP
[WATTMETERPP]

$49.95

DC INLINE WATT METER & POWER ANALYZER W/PP CONNECT

This item is currently in stock.


Introduction
This easy to use meter is ideal for monitoring eight electrical parameters that are essential to electric power safety and performance: Amps, Volts, Watts, Amp-hours, Watt-hours, Peak Amps, Minimum Volts (Sag), and Peak Watts. With a
capacity of up to 60 volts and 100 amps, high contrast blue backlit display and auto reset feature, you'll be sure find many great uses for this watt meter and power analyzer.

Safety Precautions
High power electrical systems pose many dangers. It is the user's responsibility to be familiar with these dangers and take any action necessary to ensure safe use. Shorting a battery or battery charger can have serious consequences
including explosion, fire, damage to equipment, or personal injury. Exceeding the rated specifications or shorting the watt meter will cause damage to the meter and void your warranty.

Initial Setup & Wiring
The red source wire goes to the positive (+) source or battery terminal. The black source wire (-) goes to the negative terminal. Use caution when making connections to ensure all connections are tight use adequate wire size to handle
higher amps/current. This watt meter is available with either Powerpole connectors pre-installed or with bare wire ends for installation of your own type of connectors.

Watt Meter Display Screen
Startup Screen
Each time power is applied to the watt meter (or the auxiliary power connector), the startup screen is briefly displayed. Then the Amp-hours, Watt-hours, Peak Amps, Minimum Volts, and Peak Watts parameters are all reset to zero.

Display Parameters
The display screen will continuously measure and display Amps, Volts and Watts. All other values are presented sequentially every second. In the lower left position of the display, data values are identified by their units (Ah, Wh, Ap, Vm,
Wp).

Amps (Current) & Peak Amps (A, Ap)
Only current from source to load can be measured. Drawing current in reverse will cause damage to the meter. The Amps (A) value displayed shows the average current over the last screen refresh. The Peak Amps value (Ap) displays the maximum
current drawn since the meter's last startup. Spikes or peak amperage readings lasting a fraction of a second may also be captured.

Voltage & Minimum Volts (V, Vm)
The displayed Volts (V) value is the average voltage from the last screen refresh. The displayed Minimum Volts (Vm) value is the minimum voltage or "sag" measured on the source side, since the meter's last startup.

Watt-hours (Energy) (Wh)
The displayed value is the total energy delivered in Watt-hours since the meter's last startup. It is measured from the load side for the most accurate results.

Amp-hours (Charge) (Ah)
The displayed value is the total charge delivered in Amp-hours since the meter's last startup. It is measured from the load side for the most accurate results.

Watts (Power) & Peak Watts (W, Wp)
The displayed Watts (W) value is the average Watts (Amps * Volts) from the last screen refresh. The displayed Peak Watts (Wp) value is the maximum watts measured since the meter's last startup.

Auxiliary Power Connector Cable
By connecting the watt meter directly to a battery or power source, the meter requires a minimum of 5V to power itself. However, if you are using the optional auxiliary power connector, the meter can be powered through the auxiliary source,
and measure the complete range of 0 to 60V. Another benefit of the optional auxiliary power connector is that it powers the meter through the auxiliary source. The regular source to load measurements become more precise, as the measurements
do not include the small amount of power required to operate the meter. Only 2 of the 3 wires on the auxiliary power connector are used. Refer to the watt meter black housing for (+) and (-) indicators showing how to power the watt meter
using the auxiliary input.


Specifications
Amps: 45A continuous, 100A peak, 0.01 A resolution from 1 ~ 100
Voltage: 0 ~ 60V, 0.01 V resolution (5 to 60V without optional auxiliary power connector)
Wire Type: 12 gauge wire
Watts: 0 ~ 7800W, 0.1 W resolution
Amp-hours: 0 ~ 65Ah, 0.001 Ah resolution
Watt-hours: 0 ~ 6554Wh, 0.1 Wh resolution
Display: High-contrast blue backlit LCD display
Size: 3.3 x 1.7 x 1.0" (85 x 42 x 24mm)
Weight: 0.18 lbs. (82 g)
Warranty: 1 Year Limited Warranty

Optional Accessories

JETSTREAM JT15PP1010 PACK POWER 15 AMP POWER POLE CONNECTORS $ 10.95Buy JT15PP10
JETSTREAM JT30PP1010 PACK POWER 30 AMP POWER POLE CONNECTORS $ 12.95Buy JT30PP10
JETSTREAM JT45PP1010 PACK POWER 45 AMP POWER POLE CONNECTORS $ 16.95Buy JT45PP10
POWERWERX WATTAUXCABLEAUX POWER CONNECTOR CABLE $ 3.99Buy WATTAUXCABLE
DC INLINE WATT METER & POWER ANALYZER W/PP CONNECT WATTMETERS watt meter RADIO ACCESSORIES

 

Shopping Cart more
0 items
Manufacturer Info
Other products


Follow us on Facebook



JETSTREAM
JTPS32MAB

30 Amp Power Supply
$99.95


YAESU
FT891

HF DSP
$669.95


ICOM
IC2730A

2m/70cm Mobile
$308.89

Amplifiers and Preamps
HF Amplifiers
2m Amps/Preamps
Antennas
Multiband HF Base
Multiband HF Mobile
Multiband HF Portable
2m Base
2m Mobile
Multiband VHF/UHF Base
Multiband VHF/UHF Mobile
Multiband HF/VHF/UHF Mobile
Antenna Accessories
Duplexers
Triplexers
Rotators
Antenna Mounts
Magnet Mounts
Lip Type Mounts
Antenna Tuners
HF Automatic
HF Manual
Books
Study Guides

Cable, Coax, Wire
HT Jumpers
Ground Wire
Ladderline
Mini 8/RG8X w/Connectors
RG8 w/Connectors
Rotator Cable
Connectors
Adapters
Connector End
Power Supplies
Switching 15-40 amps
Transformer 15-40 Amps
Wall Cubes
Radios
2m Handhelds
2m/70cm Handhelds
2m Mobile
2m/70cm Mobile
HF Base
HF/VHF Base
Multiband HF/VHF Mobile
Radio Accessories
Clocks
Coax Switches
External Speakers
Lightning Arrestors
SWR Analyzers
TNC/Sound Card Interfaces
Wattmeters
Tower
Rohn 25G type
Rohn 45G Type

Copyright © 2024 R&L Electronics
1315 Maple Ave
Hamilton, Ohio 45011
800-221-7735
513-868-6574 Fax
sales@randl.com